• Home
  • Product Information
  • Application Information
  • Brochure Index
  • About Adams Valves
  • News
  • Contact Us
    Block & Control Valves
    MAK
    WAK
    HTK
    OSK
    ASK/DSK
    Check Valves
    SCV
    • Assembly Drawings
    • Dimensional Drawings
    • Parts List
    • Brochure
    FCV
    RZN
    RZI
    Stop/Check Valves
    MAG-S
    GBZ/AZI

 

SCV

SCV check valves are exclusively installed at the outlet side of steam turbines. These fast closing non-return valves shall protect the turbine from back flow of steam or water which may severely damage the turbine blades.

The free swinging SCV design closes by gravity. The disc is designed to provide two times more gravitational closing force than required to overcome the frictional losses in the bearings.

Optionally, a pneumatic actuator for power assisted closing can be added. This configuration features a two piece shaft design connected by a free travel clutch (lost motion coupling). The free travel clutch is only engaged in the event of actuator closing. This design also eliminates frictional losses caused by the packings and does not negatively effect the pressure loss.

Even after installation the actuator can be mounted to the other valve side.

The standard SCV design features butt weld ends. If a flanged design is preferred welding flanges can be added.

The disc plate is made of Chromium steel to reduce abrasive effects. The top entry mounting port allows disc replacement without removing the valve from line.

The solid stainless steel seat ring is welded on the body and meets Class V tightness.

Nominal Diameters:
150 mm / 6 inch
to 800 mm / 32 inch

Pressure Class:
PN 10/16/25/40/64/100
ANSI 150/300/600

Temperature Range:
Steam up to 550 °C / 1025 °F

Design:
- Butt weld ends
- Welding flanges

Features:
- steam extraction line valve
- gravity closing
- chromium steel disc plate
- stainless steel seal fully integrated to the valve body
- seal protected from flow
- operation: free swinging or with pneumatic closing assistance

Advantages:
- ANSI / FCI 70-2 Cl. V tight shut off
- anti-blowout shaft design
- no sealing friction
- no packing friction
- low pressure loss through lost motion coupling
- high temperature compatibility
- inherently fire-safe
- low operation torques
- compact, robust construction
- low maintenance
- top entry mounting port
- field repairable

Options:
- free swinging design
- pneumatic spring return actuator as closing assistance
- welding flanges
- duct for condense water release

For further technical information or purchasing details, please contact your local Adams representative or Adams Valves, Inc.
Adams Valves Inc.   12303 Cutten Rd Houston, TX. 77066    281.453.3750    Copyright Adams Valves Inc. All Rights Reserved